Welcome: Shaanxi Guangke Titanium Industry Co., Ltd.

sales@gktitanium.com +86-19539017809

Wire and Coils

GKtitanium offers titanium wire and coil products in different grades and diameters for industrial fabrication, precision component manufacturing, and selected welding applications. Available options can be specified according to material requirements, dimensional tolerances, surface condition, and intended use.

EMAIL

Titanium wire from Ø0.1 mm to Ø8 mm in Grades 1 to 4, Grade 5, 7, 9 and 12 to ASTM B863. Welding wire and filler rod ship from stock. Fine wire is drawn to order. Both are judged on diameter consistency and what is left on the surface.

The catalog splits in two, and the split follows the buyer rather than the mill. A fabrication shop orders by AWS class, diameter and spool type. A component maker orders by temper, tolerance and surface, because the wire is about to be formed, woven or fed into a head.

Request a Wire Quote Download Wire Size List

Welding wire and rod

Welding wire, AWS A5.16 ERTi-1/2/5

Spooled wire for orbital, robotic and manual GTAW or plasma, vacuum annealed at final size and bagged with desiccant. Layer wound, because a crossed turn stalls a feeder two hours into a run.

AWS A5.16 · ASTM B863 · Ø0.8–3.2 mm · 1–15 kg spools

Straight filler rod, 1 m and 1.5 m

Cut lengths for hand TIG, end-stamped with grade and heat number, colour banded, sealed in capped tubes. Same drawing line as the spooled wire, then straightened.

AWS A5.16 · Ø1.6–4.0 mm · 1 m / 1.5 m · colour-coded

Fine wire and coils

Fine wire, Ø0.1–1.0 mm

Diamond-die drawn in Grade 1, 2, 5 and 9, annealed or cold worked to a quoted tensile range. Degreased and ultrasonically cleaned, with the cleaning route on the record.

ASTM B863 · Ø0.1–1.0 mm · ±0.005–0.02 mm · 0.1–5 kg spools

Coil and spool supply

Layer-wound coils from 0.5 kg to 15 kg on DIN 100/200 or EN ISO 544 spools, or spool-less, wound under controlled tension to a set cast and helix.

DIN 100 / 200 · EN ISO 544 S100–S300 · 0.5–15 kg

Grades and classes

GradeUNSAWS A5.16Rm min (MPa)Typical wire use
Grade 1R50250ERTi-1240Soft joints, mesh
Grade 2R50400ERTi-2345Chemical plant, TIG
Grade 3 / 4R50550 / R50700ERTi-3 / ERTi-4450 / 550Higher-strength CP
Grade 5R56400ERTi-5895Aerospace, pressure parts
Grade 7R52400ERTi-7345Reducing acid service
Grade 9R56320ERTi-9620Tube work, eyeglass wire
Grade 12R53400ERTi-12483Hot brine, crevice corrosion
Grade 23R56407ERTi-23860Implant and cryogenic

Tensile minimums follow ASTM B863 for the diameter and condition ordered. B863 governs the wire; AWS A5.16 governs the filler class. Ordering to one and expecting the other is the mix-up we see most often. How the two line up.

Diameter and coil weight

Diameter bandToleranceRm min (MPa)Standard coil / spool
Ø0.1–0.5 mm±0.005–0.01 mmGr1: 2400.1–1 kg spool
Ø0.5–1.0 mm±0.01–0.02 mmGr2: 3451–5 kg spool
Ø1.0–2.0 mm±0.02 mmGr2 345 / Gr5 8955–15 kg spool or coil
Ø2.0–3.2 mm±0.02–0.03 mmGr2 345 / Gr5 8955–15 kg, or straight
Ø3.2–8.0 mm±0.03–0.05 mmGr2: 34510–25 kg coil, or rod

These bands are typical supply, not a specification. Final diameter, ovality and coil weight are fixed against B863 and the order. Diameter is gauged at both ends of every coil, because a spool that starts at the top of the band and finishes at the bottom changes the arc without warning.

Drawing and cleaning

Rod enters at Ø5.5–8 mm, pickled and inspected. From there the wire goes through blocks of passes: carbide dies down to Ø1.0 mm, diamond below. Ductility runs out after a few passes, so the wire is vacuum annealed between blocks and once more at finished size. That last anneal is the one that matters for hydrogen. Lubricant and moisture go in at the die, and the finish anneal is what takes them back out.

After drawing comes alkaline degrease, ultrasonic clean, deionized rinse, dry, spool. Residue that survives shows up later as porosity in a weld, or as outgassing under vacuum. It is not visible on the wire, which is why the test has to be on the record instead.

Inspection

ItemDetail
MTCEN 10204 3.1: chemistry, mechanicals, hydrogen, heat number
DimensionalDiameter and ovality at both coil ends, recorded against the label
SurfaceSlivers, die lines, staining; PMI and third party on request

Packing and lead time

ItemDetail
SpoolVacuum bag, desiccant, carton or returnable shell
CoilVCI film, desiccant, ISPM-15 case, foam
Straight rodRigid tube, capped ends, grade and heat on the label
Stock lead timeon request
Drawing lead timeon request
Minimum orderon request

FAQ

Which wire for TIG on Grade 2 sheet?
ERTi-2 matches Grade 2 base metal. If the joint is formed after welding, ERTi-1 gives more ductility at a small strength cost.

AWS A5.16 or ASTM B863?
Both. A5.16 fixes filler class and chemistry, B863 the wire product and its properties. A PO quoting one usually needs the other behind it.

Lower hydrogen maximum?
Often, when the mill can vacuum anneal to that limit. Give the number in ppm and we confirm before the lot is booked.

Smallest diameter?
Ø0.1 mm in Grade 1 and Grade 2, drawn to order. Below Ø0.2 mm it is quoted per spool, because the drawing yield, not the metal, sets the price.

Quote

Send the AWS class, diameter, coil weight, process and base metal. For a critical joint add the WPS and the hydrogen limit, because those two decide the mill lot.

Request a Wire Quote

INQUIRY

CATEGORIES

CONTACT US

Contact: Jessie

Phone: +86-19539017809

E-mail: sales@gktitanium.com

Add: BLOCK A, HUIHANG PLAZA , HANGTUO ROAD, NATIONAL CIVIL AEROSPACE INDUSTRY BASE, Xi'an