A mill test certificate is worth the check you give it at goods-in, and not much more. Seven fields decide whether the certificate covers the metal in front of you. Most problems are transcription errors: a value from the wrong column, a heat number that does not match the tag, a standard quoted without its edition. Two minutes with the certificate and a caliper is cheaper than a rejected lot at the machine.
The certificate should name the material standard as the order did, with the edition: ASTM B348 for bar, ASTM B265 for plate, ASTM B381 for forgings. "Ti-6Al-4V" alone is not a standard. If the order said B348 and the certificate says AMS 4911, your drawing's approval basis no longer applies.
Grade 5 and UNS R56400 should both appear. The UNS number settles the question when a mill uses its own naming, and it is the first field to compare on a certificate from an unfamiliar mill.
The heat number ties the certificate to the piece: certificate, bundle tag, and at least one piece. If the tag names a different heat, stop there. That is the most common serious finding at goods-in, and usually a picking error rather than fraud.
Read measured values against the standard's limits, side by side. For Grade 2 the decisive numbers are oxygen (0.25% max) and iron (0.30% max); for Grade 5, aluminium (5.5–6.75%) and vanadium (3.5–4.5%); for Grade 7, palladium (0.12–0.25%). Chemistry printed without limits asks you to trust the mill's arithmetic.
Tensile, yield and elongation, with specimen orientation and test standard. Grade 2 minimums are 345 MPa tensile, 275 MPa yield and 20% elongation; Grade 5 is 895 / 828 / 10%. A certificate reporting tensile but no yield has not demonstrated the property your design was checked against. Watch units: 130 ksi is not 130 MPa.
The certificate should state the condition those values apply to (annealed, stress relieved, solution treated and aged), the treatment range where one is required, and the test temperature. For a forging, expect the heat-treatment cycle and the UT scan class. Without them the certificate is for a bar.
EN 10204 3.1 is issued by the manufacturer's own inspection department; 3.2 adds an independent inspector's endorsement. Expect the issuer's name, a certificate number, a date and your PO number. A certificate on a trader's letterhead is a real document, but it is a declaration, not a mill certificate. That distinction matters when an auditor opens the file, and it matters more while a claim is open.
| Field | Correct entry | Problem |
|---|---|---|
| Standard | ASTM B348, edition stated, form = bar | No edition, or a form standard that does not match |
| Grade | Grade 5 / UNS R56400 | Grade only, or a grade the standard does not permit |
| Heat number | Same number on cert, tag and piece | Tag heat differs from cert heat |
| Chemistry | Measured values with limits printed | Values only, or O and N missing on a CP grade |
| Mechanicals | Rm, Rp0.2, A, orientation, test standard | Tensile only, or elongation with no gauge length |
| Condition | Annealed, with cycle where required | No condition stated, or values for another condition |
| Issuer | Mill inspection, 3.1 or 3.2, dated, PO cited | Trader letterhead, no number, no date |
Every value sitting exactly on the minimum is the first. Real heats scatter, so a column that matches the specification table suggests copying rather than testing. Chemistry and mechanicals from different heat numbers on a one-lot certificate. A test date earlier than the heat date. Elongation with no gauge length, where 10% on a 4D specimen is not the same test as 10% on 5D. A Pd grade with no palladium value. One certificate covering five heats with a single tag on the pallet: ask for the split before you sign.
Three things stay outside the certificate. That the piece in your hand is the heat named, which PMI proves on a sample per heat. That it is internally sound, which takes ultrasonic inspection to a stated class. And that its dimensions are right. The dimensional check stays on your side of the goods-in door.
The checks we run before dispatch are on quality and inspection, the document set under documents and certificates, and the standard for each form on the ASTM and AMS standard page. Document sets for Grade 5 titanium bar and Grade 2 titanium bar are on the product pages.
Send the certificate and the PO number. We will run the seven fields against the order and tell you what does not line up, including when the gap is on our side.
Contact: Jessie
Phone: +86-19539017809
E-mail: sales@gktitanium.com
Add: BLOCK A, HUIHANG PLAZA , HANGTUO ROAD, NATIONAL CIVIL AEROSPACE INDUSTRY BASE, Xi'an